• Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
  • Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
  • Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
  • Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
  • Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
  • Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv

Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv

Application: Construction, Overhead, Underground, Industrial, Power Station
Voltage: Medium Voltage and High Voltage
Current: DC & AC
Insulation Material: XLPE
Sheath Material: PVC
Material Shape: Round Wire
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MV-90
Wire Core Material
Copper or Aluminum Conductor
Certification
ISO, CCC, CE, RoHS, UL, VDE, Kema
Model
Mv Cable
Brand
Rne Da
Transport Package
Standard Export Drum for Urd Cable
Specification
35-400mm2
Trademark
RNE DA
Origin
Hebei, China (Mainland)
HS Code
8544601200
Production Capacity
500km Per Month

Product Description

ICES S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 KV
Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv

Product Description:

Applications

URD - TRXLPEMLPE insulated cables are designed and manufactured to meet the applications of primary underground distribution suitable for
use in wet or dry location, direct burial, underground duct, and exposed to sunlight, To be used at 15kV upto 35kV at conductor temperatures not
to exceed 90 deg. C for normal operation.

Specifications

TRXLPEMLP insulated URD cables meets or exceeds all applicable requirements of thefollowing standards, and guaranteed
all cables manufactured and tested under this standards.

- ANSIIICEA S94-649

- AEIC CS-8

- ASTM B-3, ASTM B-8, ASTM B-230 & ASTM B-231 

Construction

Conductor : Bare aluminium or copper, stranded class B compressed stranding

Conductor Shield :Extruded semi-conducting compound

Insulation : TRXLP (TreeRetardant XLPE) or XLPE

Insulation Shield : Extruded semi-conducting compound

Concentric Neutral : Uncoated copper concentric neutral wires (coated copper are optional)

Encapsulated Jacket : Non-conducting LLDPE embedded jacket with extruded red stripes.

PVC or Semi-conducting jacket are available upon request
 

Maximum Conductor Temerature

Normal continuous at 90 ºC, Overload at 130  ºC and Short circuit at 250   ºC

Features & Neneritas, Options

- Triple extruded construction by dry curing process guarantees excellent quality of cables

- TRXLPE insulation offers proven superior life span than conventional XLPE cables

- Triplex type is optional, it brings you saving installation cost

- Strand-filled conductor & Water-blocking jacket is available upon request 

Data Sheet

Conductor Copper Neutral  (1/3) Diameter(inch) Weight (Pounds)
AWG
 or
MCM
Stranding Number
of 
Wires
Size
AWG
Conductor Over
Insulation
Over
Insul.
Shield
Over
 Neutral
Wires
Over
Embedded.
Jkt.
Conductor Concentric
Neutral
Total
No
Jacket
Total
With
Jacket
1/0 19 wire 9 14 0.37 1.12 1.23 1.35 1.46 325.8 119.2 659 4926
2/0 19 wire 11 14 0.42 1.17 1.27 1.40 1.50 410.9 146.3 775 808
3/0 19 wire 14 14 0.47 1.22 1.32 1.48 1.59 518.1 185.9 900 923
4/0 19 wire 11 12 0.53 1.28 1.38 1.54 1.71 653.3 228.0 1110 1055
250 37 wire 13 12 0.57 1.33 1.44 1.64 1.81 771.9 282.1 1330 1292
350 37 wire 12 10 0.68 1.44 1.54 1.70 1.89 1081 398.0 1633 1519
500 37 wire 17 10 0.81 1.57 1.72 1.88 2.04 1544 543.5 2002 1886
750 61 wire 25 10 0.99 1.76 1.93 2.11 2.28 2316 801.5 2650 2289
1000 61 wire 33 10 1.14 1.92 2.06 2.27 2.43 3088 1058 3847 2960

 
Package
Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv

Company


Hebei huatong wires&cables Group Co.,ltd.It was established in 1993, we are JV with Furukawa (Japanese company) for rubber serious cables and JV with Riken(Japanese company) for elevator cables. Besides these,our submersible oil pump cable and shipboard cable are very influential in domestic, and, the traditional cables are also produced such as PVC powercables, XLPE power cables, ABC cables, wires, control
cables, screened cables,communication cables, conductors.We areOEM for many USA, Europen, Australia cable company,70% of our products are exported, most customers are from developed countries. We got ISO,UL,TUV,KEMA,CE and many other certifications.


Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv

Certification


Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
Laboratory


Ices S-94-649 Standard Trxlpe Insulation Concentric Neutral (PE) LLDPE Jacket Underground Distribution Cable 15-35 Kv
FAQ

(1).When can I get the price?

We usually quote within 6 hours after we get your inquiry. If you are very urgent to get the price, please call us or tell us in your e-mail so that we
will regard your inquiry priority.

(2).How can I get a sample to check your quality?

After price confirmation, you can require for samples to check our quality. Sample is free, but the freight charge should be paid.

(3).How long can I expect to get the sample?

After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7days. The samples will be sent to you
via express and arrive in 3~5 days. You can use your own express account orprepay us if you do not have an account.

(4).What about the lead time for mass production?

Honestly, it depends on the order quantity and the season you place the order.The best record we keep is delivering 10 kilometers cable within
a week
. Generally speaking, we suggest that you start inquiry two months before the date you would like to get the products at your country.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018