Type: Insulated
Conductor Type: Solid or Stranded
Application: Indoor Building Wire or Air Condictioner
Conductor Material: Copper
Sheath Material: PVC
Insulation Material: PVC
Samples:
US$ 1/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
14/2 12/2 10/2 10/3 12/3 8/3 6/3 2/3
Material Shape
Flat or Round
Range of Application
Cold-Resistant
Certification
ISO9001, CE, CCC, RoHS, CSA cUL
Brand
Ht Cables
Voltage
300V
Size Range
14/2 to 2/3
Temperature
-40c to 90c
Low Cold Area
-40c or -25c
Transport Package
150m or 75m Per Reel
Specification
290*210*290mm
Trademark
HT CABLES
Origin
China
HS Code
8544492100
Production Capacity
21600000m Per Week

Product Description

cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture
             cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture
 CSA certificate  300V NMD 90 NMWU90  Building Wires

                                                                       - 14/2 to 2/3  Indoor Non-Metallic Cable  150m or 75m per reel 
Application:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or
damp locations.The maximum allowable conductor temperature is 90°C. The minimum
recommended installation temperature is -25°C or -40°C for two-conductor cables and -25°C for
three-conductor cables (with suitable handling procedures). Material should be properly stored
above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended
applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to
applications.
Structure:
1. Conductor: Copper conductor with Copper grounding wire 14AWG to 2AWG
or aluminium alloy 8000series ACM with AL groundig wire Grey 6AWG to 2AWG.
2. Insulation: Polyvinyl chloride (PVC)
3. Protective covering: nylon
4. Jacket: PVC, Heat and moisture-resistant, flame retardant FT1.
5. Number of conductor: 2 parell laid or 3 and 4 round laid
Standard:
CSA C22.2 No. 48 (non-metallic sheathed cable)
 
CSA File No.:
Master Contract: 271587 ,  
Certificate:
80169079
 
Voltage:
300V
Working temperature:
in dry locations only at temperature not to exceed 90°C.
 
Performance:
FT-1 Flame retardant; Heat and moisture-resistant
 
Printing:
HT CABLES c(UL) E487898 14AWG 2C NMD90 NYLON CABLE FT1 300V (-25ºC) xxx m 2023
 
Jacket Color:
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors  for air condictioner 
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors
 
Technical data:
Conductor Grounding Wire Jacket Thickness OD Weight Max. DC resistance at 20C (Ω/km)
Size        AWG NO. No. of strands Insulation Thickness Nylon Thickness Size ( AWG) No. of Strands
  mm mm     mm mm kg/km
14 2 1 0.76 0.13 14 1 0.76 4.9 x 9.9 108.9 8.62
12 2 1 0.76 0.13 14 1 0.76 5.3 x 11.2 148.8 5.43
10 2 1 0.76 0.13 12 1 0.76 5.9 x 12.8 209.9 3.41
8 2 7 0.89 0.16 10 1 1.14 8.1 x 16.4 324.1 2.14
6 2 7 1.14 0.2 8 7 1.14 9.6 x 20.2 487.2 1.36
14 3 1 0.76 0.13 14 1 0.76 8.8 136.5 8.62
12 3 1 0.76 0.13 14 1 0.76 9.8 177.9 5.43
10 3 1 0.76 0.13 12 1 0.76 11 249.7 3.41
8 3 7 0.89 0.16 10 1 1.14 14.8 418.7 2.14
6 3 7 1.14 0.2 8 7 1.14 18.1 634.4 1.36
4 3 7 1.14 0.2 8 7 1.52 21.4 917.3 0.848
3 3 7 1.14 0.2 6 7 2.03 24.1 1188 0.673
2 3 7 1.14 0.2 6 7 2.03 25.8 1400.9 0.534
14 3 1 0.76 0.13 14 1 0.76 8.8 169.2 8.62
12 3 1 0.76 0.13 14 1 0.76 9.8 222.7 5.43
10 3 1 0.76 0.13 12 1 0.76 11 316.2 3.41
8 3 7 0.89 0.16 10 1 1.14 14.8 524.4 2.14
6 3 7 1.14 0.2 8 7 1.14 18.1 800 1.36
4 3 7 1.14 0.2 8 7 1.52 21.4 1163.3 0.848
3 3 7 1.14 0.2 6 7 2.03 24.1 1497.8 0.673
2 3 7 1.14 0.2 6 7 2.03 25.8 1776.2 0.534
             cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture             cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture               
                NMD90 XLPE AL Wire

 
Application:

NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C or -40°C for two-conductor cables and -25°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further information related to applications.

Structure:
  1.  Conductor: aluminium alloy 8000series ACM with AL groundig wire Grey  6AWG to 2AWG.
  2.  Insulation: crosslinked polyethylene (XLPE)
  3.  Jacket: PVC, Heat and moisture-resistant, flame retardant FT1.
  1. Number of conductor: 3 and 4 round laid

Standard:
CSA C22.2 No. 48 (non-metallic sheathed cable)
UL File No.: 

E487898

Voltage:
300V

Working temperature:
in dry locations only at temperature not to exceed 90°C.

Performance:
FT-1 Flame retardant; Heat and moisture-resistant
Printing:
HT CABLES c(UL) E487898 6AWG 3C AL ACM NMD90 NYLON CABLE FT1 300V (-25ºC)    xxx m  2023

Jacket Color:   Grey

Technical data:
 
Conductor Grounding Wire Jacket Thickness Cable Dimensions Weight Max. DC resistance at 20C (Ω/km)
Size        AWG NO. No. of strands Insulation Thickness Nylon Thickness Size            ( AWG) No. of Strands
mm mm mm mm kg/km
8 3 7 0.89 0.16 10 1 1.14 14.8 231.8 3.52
6 3 7 1.14 0.2 8 7 1.14 18.1 337.6 2.21
4 3 7 1.14 0.2 8 7 1.52 21.4 475.6 1.39
3 3 7 1.14 0.2 6 7 2.03 24.1 614.7 1.1
2 3 7 1.14 0.2 6 7 2.03 25.8 701.2 0.875
8 4 7 0.89 0.16 10 1 1.14 14.8 285.9 3.52
6 4 7 1.14 0.2 8 7 1.14 18.1 421.4 2.21
4 4 7 1.14 0.2 8 7 1.52 21.4 591.4 1.39
3 4 7 1.14 0.2 6 7 2.03 24.1 760.7 1.1
2 4 7 1.14 0.2 6 7 2.03 25.8 870.6 0.875
cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture
cUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire ManufacturecUL Listed CSA Certificate Nmd90 Nmwu90 Building Wire Manufacture

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018