• UL 1569 Thhn Inner Mc/AC/Bx Cable
  • UL 1569 Thhn Inner Mc/AC/Bx Cable
  • UL 1569 Thhn Inner Mc/AC/Bx Cable
  • UL 1569 Thhn Inner Mc/AC/Bx Cable
  • UL 1569 Thhn Inner Mc/AC/Bx Cable

UL 1569 Thhn Inner Mc/AC/Bx Cable

Type: Insulated
Conductor Type: Solid
Application: Underground
Conductor Material: Copper or Aluminum
Sheath Material: PVC
Insulation Material: PVC
Samples:
US$ 0/Meter 1 Meter(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
MC/AC/BX CABLE
Material Shape
Round Wire
Range of Application
Commercial, Industrial
Certification
ISO9001, CE, CCC, RoHS, VDE
Brand
Huatong
Voltage
Low Voltage 600V, 2000V
Armored Material
Aluminum/Steel Interlock
Transport Package
Coils and Drums
Specification
12AWG to 2000KCMIL
Trademark
Renda
Origin
China
HS Code
8544492100
Production Capacity
200000m/Month

Product Description

 
 
 
APPLICATION
Type MC Cable - Isolated Ground is constructed with soft-drawn copper, Type THHN/THWN
conductors rated 90°C dry available in sizes 12 AWG and 10 AWG, and two insulated grounding conductors--one solid green and the second green with yellow stripes. The conductors are cabled together and a binder tape bearing the print legend is
wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. 

Type AC Cable BX is constructed with soft-drawn copper, Type THHN insulated conductors which are
individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.


 
Power Tray Cable Applications
  • Type MC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
    • Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
 
  • Type AC Cable is suitable for use as follows:
    • Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
    • Power, lighting, control, and signal circuits.
    • Dry locations only.
    • Fished or embedded in plaster.
    • Concealed or exposed installations.
    • Environmental air-handling spaces per NEC 300.22 (C).
    • Installation in cable tray and approved raceways.
    • Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).

STANDARDS & REFERENCES

Type AC Cable meet or exceeds the following requirements
• UL 4, 83, 1581, 2556
• Federal Specification A-A59544 (formerly J-C-30B)
• National Electrical Code Article 320 Armored Cable: Type AC

Type MC Cable meets or exceeds the requirements of the following
• UL 83
• UL 1569
• UL 1685
• Federal Specification A-A59544 (formerly J-C-30B)
• FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
• NEC
• Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

CONSTRUCTION

Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry
available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.

Type AC Cable is constructed with soft-drawn copper, Type THHN insulated conductors which are
individually wrapped with a moisture-resistant, flame-retardant paper covering. Aluminum interlocking armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length.
.
Conductor Size  Solid or Stranded  Grounding Conductor Size  Overall Diameter Weight  Ampacity (Amps)
 (AWG)   (AWG)  (inches)  (lbs./1000ft.)  60 75 90
14-2 Solid  14 0.439 77 15 15 15
14-3 Solid  14 0.464 94 15 15 15
14-4 Solid  14 0.494 112 15 15 15
12-2 Solid  12 0.527 137 20 20 20
12-3 Solid  12 0.505 129 20 20 20
12-4 Solid  12 0.539 155 20 20 20
10-2 Solid  10 0.542 150 30 30 30
10-3 Solid  10 0.58 189 30 30 30
10-4 Solid  10 0.623 229 30 30 30
 


UL 1569 Thhn Inner Mc/AC/Bx Cable

 
UL 1569 Thhn Inner Mc/AC/Bx CableUL 1569 Thhn Inner Mc/AC/Bx CableUL 1569 Thhn Inner Mc/AC/Bx CableUL 1569 Thhn Inner Mc/AC/Bx CableUL 1569 Thhn Inner Mc/AC/Bx CableUL 1569 Thhn Inner Mc/AC/Bx Cable

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018