Product Description
14/2 12/2 12-2 14-2 nmd90 w/g Electric coper wire and cable 15ft 25ft 50ft 100ft 250ft 100' 250' roll with Ground
Applications:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.
The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further
information related to applications.
Codes / Standards
NMD90 cables meet or exceed the following requirements:
CONSTRUCTION
Canada standard C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code1
NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is
manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a
heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.
Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below
JACKET COLOUR CODE - Typical Application Guide
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
CABLE PRINTING
12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON 300 VOLTS FT1
NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external
lubricants, resulting in reduced labour and materials costs.
PVC / NYLON INSULATION
PVC JACKET
GROUND CONDUCTOR COPPER CONDUCTOR PVC / NYLON INSULATION
PVC JACKET
Specification:
Size |
Number of Conductors |
Bonding Wire Size (Copper) |
Insulation Thickness |
Nylon Thicknes |
Jacket Thickness |
Approximate Overall Dimensions |
Approximate Net Cable Weight |
Ampacity 30°C Ambient |
AWG |
|
AWG |
mm |
mm |
mm |
mm |
kg/km |
A |
14 |
2 |
14 |
0.76 |
0.1 |
0.76 |
4.9 x 9.9 |
99 |
15 |
12 |
2 |
14 |
0.76 |
0.1 |
0.76 |
5.3 x 10.7 |
127 |
20 |
10 |
2 |
12 |
0.76 |
0.1 |
0.76 |
5.9 x 12.2 |
181 |
30 |
|
|
|
|
|
|
(diameter) |
|
|
14 |
3 |
14 |
0.76 |
0.1 |
0.76 |
8.8 |
126 |
15 |
12 |
3 |
14 |
0.76 |
0.1 |
0.76 |
9.7 |
166 |
20 |
10 |
3 |
12 |
0.76 |
0.1 |
0.76 |
10.9 |
239 |
30 |
8 |
3 |
10 |
0.89 |
0.12 |
1.14 |
14.1 |
391 |
45 |
6 |
3 |
8 |
1.14 |
0.15 |
1.14 |
17.2 |
601 |
65 |
4 |
3 |
8 |
1.14 |
0.15 |
1.52 |
20.3 |
876 |
85 |
3 |
3 |
6 |
1.14 |
0.15 |
2.03 |
22.8 |
1136 |
105 |
2 |
3 |
6 |
1.14 |
0.15 |
2.03 |
24.4 |
1355 |
120 |