6 AWG Indoor Non-Metallic Wire NMD90 Wire Electrical Wire CUL Certificate
TOP TEN CABLE MANUFACTURER IN CHINA
LARGEST CABLE MANUFACTUER IN NORTH CHINA
ANNUAL EXPORT VOLUME EXCEED 200MILLION USD
WITH UL,TUV,KEMA,CE,BV,PSB,SABS,LLOYD'S,GL,NK,KR,ABS PRODUCTS CERTIFICATIONS
WITH TUV TYPE TESTING REPORT
WIDE PRODUCTS RANGE
ISO9001,ISO18001,OHSAS18001 SYSTEM CERTIFICATIONS
CNAS APPROVAL LABROTARY
Applications:
NMD90 cables may be used for both exposed work in dry locations or concealed work in dry or damp locations.
The maximum allowable conductor temperature is 90°C. The minimum recommended installation temperature is -25°C for two-conductor cables and -10°C for three-conductor cables (with suitable handling procedures). Material should be properly stored above 0°C for 24 hours prior to installation. The maximum voltage rating for all intended applications is 300 volts. Consult the Canadian Electrical Code1 for further
information related to applications.
Codes / Standards
NMD90 cables meet or exceed the following requirements:
CONSTRUCTION
Canada standard C22.2 No. 48 (non-metallic sheathed cable)
Canadian Electrical Code1
NMD90 cables are available as two- or three-conductor cables with a bare grounding conductor. It is
manufactured using annealed (soft) copper conductors-compressed standing for stranded conductors; a
heat-resistant thermoplastic polyvinyl chloride (PVC) insulation and nylon jacket for the individual conductors with a PVC jacket for the overall construction.
Conductors are white, black and red (for 3 conductor cables). Cable jackets are colour coded by size for quick identification in the Table below
JACKET COLOUR CODE - Typical Application Guide
•WHITE - General Residential Wiring
•RED - 2 Black and Red conductors - 208V-240V Circuits (no neutral)
•ORANGE - No. 10 AWG General Residential Wiring
•YELLOW - No. 12 AWG General Residential Wiring
•BLUE - No. 14 AWG - 2 black and white conductors - 120V Arc Fault Circuit Interupter Applications
CABLE PRINTING
12 AWG 2 CDRS BLACK/WHITE NMD90 NYLON 300 VOLTS FT1
NMD90 jackets which reduces the coefficient of friction, allowing cables to be installed without external
lubricants, resulting in reduced labour and materials costs.
PVC / NYLON INSULATION
PVC JACKET
GROUND CONDUCTOR COPPER CONDUCTOR PVC / NYLON INSULATION
PVC JACKET
Specification:
Size |
Number of Conductors |
Bonding Wire Size (Copper) |
Insulation Thickness |
Nylon Thicknes |
Jacket Thickness |
Approximate Overall Dimensions |
Approximate Net Cable Weight |
Ampacity 30°C Ambient |
AWG |
|
AWG |
mm |
mm |
mm |
mm |
kg/km |
A |
14 |
2 |
14 |
0.76 |
0.1 |
0.76 |
4.9 x 9.9 |
99 |
15 |
12 |
2 |
14 |
0.76 |
0.1 |
0.76 |
5.3 x 10.7 |
127 |
20 |
10 |
2 |
12 |
0.76 |
0.1 |
0.76 |
5.9 x 12.2 |
181 |
30 |
|
|
|
|
|
|
(diameter) |
|
|
14 |
3 |
14 |
0.76 |
0.1 |
0.76 |
8.8 |
126 |
15 |
12 |
3 |
14 |
0.76 |
0.1 |
0.76 |
9.7 |
166 |
20 |
10 |
3 |
12 |
0.76 |
0.1 |
0.76 |
10.9 |
239 |
30 |
8 |
3 |
10 |
0.89 |
0.12 |
1.14 |
14.1 |
391 |
45 |
6 |
3 |
8 |
1.14 |
0.15 |
1.14 |
17.2 |
601 |
65 |
4 |
3 |
8 |
1.14 |
0.15 |
1.52 |
20.3 |
876 |
85 |
3 |
3 |
6 |
1.14 |
0.15 |
2.03 |
22.8 |
1136 |
105 |
2 |
3 |
6 |
1.14 |
0.15 |
2.03 |
24.4 |
1355 |
120 |
NMD90 Packing picture
Other cables we can offer in the North American market:
1. Service entrance cable
2. SEU/SER/SE
3. XHHW/RHW/RHH
4. MV 90/105 URD
5. THW/THHN/THWN
6. MC/AC/AC90/TECK series cables
7. Portable power cable( type SOOW, G, G-GC, SHD-GC)
8. welding cable
9. photo voltaic(PV) wire
10. diesel locomotive cable
11. power and control tray cable
12. bus drop cable
13. DG cable
14. shipboard cable
15. telecommunication cables
16. AC cables
17. AWM cables