UL 854 Service Entrance Cable
Aluminum/Copper Type SE, Style R/U SEU 4/0 4/0 2/0
APPLICATION
Type SE, service entrance cable is primarily used to convey power from the service drop to the meter base and from the meter base to the distribution panelboard; however, the cable may be used in all applications where Type SE cable is permitted. SER may be used in wet or dry locations at temperatures not to exceed 90°C. The voltage rating is 600 volts.
PRODUCT FEATURES
- Type SE cable is constructed with AA-8000 series aluminum alloy, compact stranded conductors.
- Cross-linked polyethylene insulation rated for a maximum operating temperature of 90°C in wet and dry locations.
- Eco-friendly sunlight resistant, flame retardant and heavy metal-free Polyvinyl Chloride (PVC) Jacket.
- Insulation and Jacket materials are in compliance with RoHS, Directive 2002/95/EC.
- Sequential foot markings for easier inventory control management.
STANDARDS & REFERENCES
Type SE cable complies with :
• ASTM- All applicable standards
• UL Standard 44 for XHHW-2 conductors
• UL Standard 83 for THHN/THWN conductors
• UL Standard 854
• Federal Specification A-A-59544
• National Electrical Code, NFPA 70. 2011 Edition
• RoHS/ REACH
CONSTRUCTION
Conductor: compact copper or AA-8000 series aluminum alloy, compact stranded
Insulation: Cross-linked polyethylene(XLPE) insulation with the property of heat.Moisture and abrasion resistance and flame retardant.
Sheath: sunlight resistant gray polyvinyl chloride (PVC).
Type SE cable is constructed with sunlight resistant Type XHHW-2 conductors or Type THHN/THWN conductors.Cable assembly plus reinforcement tape are jacketed with sunlight resistant gray polyvinyl chloride (PVC). Available as 1 conductor with a concentric ground, 2 conductor with a round or concentric
ground, or 3 conductor with a bare ground. SE cable is jacketed with gray sunlight-resistant polyvinyl chloride (PVC).
Aluminum Specifications:
Service Entrance Cable Style R (SER) - 2 Conductor with Ground SER |
Size AWG &
Construction |
Stranding |
Nominal |
Weight per |
Ampacity (AMPS) * |
Diameter |
1000 ft. |
Phase |
Equipment Ground |
(in) |
(lbs) |
90˚ C |
Dwelling |
Conductors |
Conductor |
|
|
6-6-6 |
7 |
- |
0.65 |
150 |
60 |
- |
4-4-6 |
7 |
- |
0.681 |
196 |
75 |
- |
4/4/4 |
7 |
- |
0.682 |
196 |
75 |
- |
|
Service Entrance Cable Style R (SER) - 3 Conductor with Ground SER |
Size AWG &
Construction |
Stranding |
Nominal |
Weight per |
Ampacity (AMPS) * |
Diameter |
1000 ft. |
Phase |
Equipment Ground |
(in) |
(lbs) |
90˚ C |
Dwelling |
Conductors |
Conductor |
|
|
8-8-8-8 |
Solid |
Solid |
0.588 |
128 |
45 |
- |
6-6-6-6 |
7 |
7 |
0.684 |
180 |
60 |
- |
4-4-4-6 |
7 |
7 |
0.754 |
240 |
75 |
- |
2-2-2-4 |
7 |
7 |
0.893 |
344 |
100 |
100 |
1-1-1-3 |
19 |
7 |
1.003 |
432 |
115 |
110 |
1/0-1/0-1/0-2 |
19 |
7 |
1.097 |
521 |
135 |
125 |
2/0-2/0-2/0-1 |
19 |
19 |
1.197 |
633 |
150 |
150 |
3/0-3/0-3/0-1/0 |
19 |
19 |
1.314 |
771 |
175 |
175 |
4/0-4/0-4/0-2/0 |
19 |
19 |
1.443 |
942 |
205 |
200 |
250-250-250-3/0 |
37 |
19 |
1.601 |
1106 |
230 |
225 |
|
Service Entrance Cable Style R (SER) - 4 Conductor with Ground SER |
Size AWG &
Construction |
Stranding |
Nominal |
Weight per |
Ampacity (AMPS) * |
Diameter |
1000 ft. |
Phase |
Equipment Ground |
(in) |
(lbs) |
90˚ C |
Dwelling |
Conductors |
Conductor |
|
|
2-2-2-2-4 |
7 |
7 |
1.004 |
450 |
100 |
100 |
2/0-2/0-2/0-2/0-1 |
19 |
19 |
1.346 |
824 |
150 |
150 |
4/0-4/0-4/0-4/0-2/0 |
19 |
19 |
1.621 |
1226 |
205 |
200 |
250-250-250-250-3/0 |
37 |
19 |
1.95 |
1454 |
230 |
225 |
1. Data are approximate and subject to normal manufacturing tolerances.
2. Standard lengths are subject to normal manufacturing tolerance of +/- 10%
3.
To determine correct ampacity by conductor size, please consult the National Electric Code, latest edition.
4. Table values reflect XHHW-2 aluminum conductors
5.Package:A-500' B-2,500' C-1,000' D-5,000'
UL Certificate for XHHW,SER,SEU,MC Cable