Product Description
UL 44, Type XHHW-2 Thermoset-Insulated Wires and Cables
APPLICATION
Aluminum conductors are primarily used in conduit or recognized raceways for service and feeder wiring as specified in the National Electrical Code. XHHW-2 conductors may be used in wet or dry locations at temperatures not to exceed 90°C. Voltage rating for XHHW-2 conductors is 600 volts. Suitable for use in Health Care Facilities per section 517.160 of the NEC where a dielectric constant of 3.5 or less may be specified. This product is designed to be installed without the application of pulling lubricant.
PRODUCT FEATURES
Compact stranded 8000 Series aluminum alloy conductor. Insulation is an abrasion, moisture, heat and sunlight resistant black cross-linked polyethylene.
Cable can be installed without pulling lubricant.
CT rated available when requested on sizes 1/0 AWG and larger.
STANDARDS & REFERENCES
Aluminum Type XHHW-2 conductors comply with the following:
• ASTM- All Applicable Standards
• UL Standard 44
• UL listed as Type XHHW-2.
• NOM-ANCE 90° C
• Federal Specification A-A-59544
• National Electrical Code, NFPA 70, 2014 Edition
• NEMA WC-70 (ICEA S-95-658) Construction Requirements
• RoHS/Reach Compliant
Conductor sizes 6 AWG and larger are listed and marked sunlight resistant in all colors.
CONSTRUCTION
Conductor: compact copper or AA-8000 series aluminum alloy, compact stranded
Insulation:Cross-linked polyethylene(XLPE) insulation with property of heat.Moistrure and abrasion resistance and flame retardant.
Color :Available in black, white, red, blue, brown, orange, yellow, purple, gray, and green.
Specifications
Conductor (AWG or MCM) |
Stranding |
Insulation |
Outside |
Weight per 1000 ft. |
Ampacity |
Thickness |
Diameter |
(AMPS) * |
(mls) |
(in) |
(lbs) |
90° C |
6 |
7/w |
45 |
0.26 |
39 |
60 |
4 |
7/w |
45 |
0.305 |
57 |
75 |
2 |
7/w |
45 |
0.36 |
84 |
100 |
1 |
19/w |
55 |
0.415 |
108 |
115 |
1/0 |
19/w |
55 |
0.45 |
132 |
135 |
2/0 |
19/w |
55 |
0.49 |
161 |
150 |
3/0 |
19/w |
55 |
0.54 |
198 |
175 |
4/0 |
19/w |
55 |
0.59 |
244 |
205 |
250 |
37/w |
65 |
0.655 |
292 |
230 |
300 |
37/w |
65 |
0.705 |
344 |
255 |
350 |
37/w |
65 |
0.75 |
396 |
280 |
400 |
37/w |
65 |
0.795 |
448 |
305 |
500 |
37/w |
65 |
0.87 |
550 |
350 |
600 |
61/w |
80 |
0.98 |
671 |
385 |
700 |
61/w |
80 |
1.04 |
774 |
420 |
750 |
61/w |
80 |
1.075 |
824 |
435 |
900 |
61/w |
80 |
1.161 |
0.979 |
480 |
1000 |
61/w |
80 |
1.23 |
1079 |
500 |
1. Data are approximate and subject to normal manufacturing tolerances.
2. Standard lengths are subject to normal manufacturing tolerance of +/- 10%
3. Two, Three or four conductors can be paralleled on a reel.
4. 90°C- XHHW-2 wet or dry locations.
5.Package:A-500' B-2,500' C-1,000' D-5,000'