10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable

Product Details
Customization: Available
Application: Construction, Overhead, Industrial, Power Station
Voltage: Low and Medium Voltage Cable
Still deciding? Get samples of US$ 1/Meter
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Industry-leading Audited Factory

Secured Trading Service
Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (29)
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
  • 10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable
Find Similar Products

Basic Info.

Model NO.
NM-B cable
Current
DC Cable
Insulation Material
PVC
Sheath Material
PVC
Material Shape
Round Wire
Wire Core Material
Bare Copper Wire
Certification
ISO, CCC, CE, RoHS, VDE
Model
Nm-B
Brand
Rneda
Transport Package
Soft Packing
Specification
NM-B
Trademark
RNEDA
Origin
Hebei, China (Mainland)
HS Code
8544492100
Production Capacity
100000 Meters

Product Description

10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable


10/2 10/3 UL Listed building Wire Copper Conductor PVC Insulation Nm-B 600V Cable 
 



Applications:

Type NM-B (Non-metallic sheathed cable) has a broad range of usage as defined in Article 334 of the National Electrical Code (NEC). Type NM-B cable is commonly used for residential fixtures, switches, and loads rated for at least 90ºC. Type NM-B ampacity limitation shall be in accordance with the 60ºC conductor temperature rating, as specified in the National Electrical Code. Type NM-B is rated for 600 volts for both exposed and concealed work in normally dry locations. Type NM-B may be installed or fished in air voids and joints and in masonry block or tile walls where such walls are not exposed to, nor subject to, excessive moisture or dampness.


Standards:
Underwriters Laboratories Standards UL-83, UL-719
Federal Specification A-A-59544
ASTM-B3 and B8
ARRA 2009; Section 1605 "Buy American" Compliant

CONSTRUCTION:
Conductors:
Solid 14-10 AWG soft, uncoated copper, per ASTM-B3
Stranded 8 AWG conductor and larger uncoated, copper ASTM-B8
Insulation:
Color-coded Polyvinyl Chloride (PVC) compound meeting the required thickness of Type THHN with a heat-stabilized Nylon jacket rated for 90°C in dry locations.
Grounding Conductor:
Soft, uncoated copper per ASTM-B3 and/or ASTM-B8
Jacket:
A 30-mil, color-coded, PVC jacket is applied over the completed assembly as follows:
14 AWG White I 12 AWG Yellow I 10 AWG Orange I 8 AWG Black I 6 AWG Black

Assembly:
2-conductor construction has the insulated conductors laid parallel with a bare copper ground wire wrapped in paper and laid parallel between the insulated conductors. The entire assembly is wrapped with a paper separator before applying the PVC outer jacket. SuperSlick Elite is available in sizes: 14 AWG, 12 AWG, 10 AWG constructions. 3 and 4 conductor constructions may have the insulated conductors laid parallel or twisted together before applying the PVC outer jacket.

Specification:

Size (AWG) Number of strands in the conductor Insulation Min. Thickness of nylon (mm) Size of grounding core (AWG) Jacket thicknes (mm) Approx. OD L*H (mm)
Thickness
mm
14/2 1 0.38 0.1 14 0.76 4.5*9.1
12/2 1 0.38 0.1 12 0.76 4.9*10.4
10/2 1 0.51 0.1 10 0.76 5.7*12.5
8/2 7 0.76 0.13 10 0.76 7.4*15.9
6/2 7 0.76 0.13 10 0.76 8.4*17.5
14/3 1 0.38 0.1 14 0.76 4.5*11.3
12/3 1 0.38 0.1 12 0.76 4.9*13.4
10/3 1 0.51 0.1 10 0.76 5.7*15.9
8/3 7 0.76 0.13 10 0.76 7.4*21.1
6/3 7 0.76 0.13 10 0.76 8.4*23.9
10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable10/2 10/3 UL Listed Building Wire Copper Conductor PVC Insulation Nm-B 600V Cable