Features:
Sunlight, ozone, and UV resistant
Moisture resistant
RoHS compliant
REACH compliant
-40°C to +150°C temperature range
Standards:
UL-4703, UL-854, UL-44
UL 1685-FT4/IEEE 1202 (70,000 Btu/hr) Flame Test (1/0 AWG and larger)
ICEA T-29-520 (210,000 Btu/hr) Flame Test
NEMA WC70/ICEA S-95-658
NFPA 70: National Electrical Code (NEC)
Conductors:
Al alloy Stranded conductors, or uncoated copper per ASTM-B787 and ASTM-B8
Insulation:
Cross-linked polyethylene (XLP) insulation per UL-854, UL-4703 and UL-44
voltage:
600v,1000v,2000v
Applications:
Type Photovoltaic copper conductors are suitable for outdoor rooftop applications without conduit and for use in conduits and raceways installed underground in conduit in wet locations, and where condensation and moisture accumulations within the conduit do not exceed 90ºC. Applications requiring direct burial is permitted for Type Photovoltaic per UL-854. Applications requiring type Photovoltaic conductor, temperatures shall not exceed 90ºC in wet or dry locations.
Features:
Available in 600V and 1000V/2000V. All cables comply with UL's VW-1 (Vertical Wire) Flame Test. Insulation compounds are rated for flame and sunlight-resistance in all sizes and colors. Photovoltaic conductors of 1/0 through 1000 KCMIL are rated for CT use. Sequential foot markings located every foot on master reels only for 1 AWG through 1000 KCMIL unless otherwise specified. RoHS compliant. Flexibility at Low Temperature Test. Carries -40 °C rating.
Insulation Thickness XLPE mm | Outside Diameter mm | Allowable Ampacity(Amps) | Approximate Net Weight(lbs/1000 ft) | |||||||
Number of | ||||||||||
Strands | ||||||||||
SizeAWG | 600V | 1000V | 600V | 1000V | 600V | 1000V | 600V | 1000V | 600V | 1000V |
2000V | 2000V | 2000V | 2000V | 2000V | ||||||
14 | 19 | 19 | 0.06 | 0.075 | 4.89 | 5.61 | 25 | 25 | 24 | 28 |
12 | 19 | 19 | 0.06 | 0.075 | 5.37 | 6.05 | 30 | 30 | 33 | 38 |
10 | 19 | 19 | 0.06 | 0.075 | 5.99 | 6.6 | 40 | 40 | 47 | 52 |
8 | 7* | 7* | 0.075 | 0.085 | 7.52 | 7.95 | 55 | 55 | 74 | 78 |
6 | 7* | 7* | 0.075 | 0.085 | 8.48 | 8.86 | 75 | 75 | 108 | 113 |
4 | 7* | 7* | 0.075 | 0.085 | 9.7 | 10.06 | 95 | 95 | 161 | 166 |
3 | 7* | 7* | 0.075 | 0.085 | 10.41 | 10.77 | 110 | 110 | 197 | 203 |
2 | 7* | 7* | 0.075 | 0.085 | 11.23 | 11.58 | 130 | 130 | 243 | 249 |
1 | 19 | 19 | 0.095 | 0.105 | 13.16 | 13.49 | 150 | 150 | 313 | 320 |
1/0 | 19 | 19 | 0.095 | 0.105 | 13.97 | 14.48 | 170 | 170 | 380 | 389 |
2/0 | 19 | 19 | 0.095 | 0.105 | 15.09 | 15.6 | 195 | 195 | 476 | 484 |
3/0 | 19 | 19 | 0.095 | 0.105 | 16.36 | 16.87 | 225 | 225 | 590 | 599 |
4/0 | 19 | 19 | 0.095 | 0.105 | 17.78 | 18.29 | 260 | 260 | 732 | 742 |
250 | 37 | 37 | 0.11 | 0.12 | 19.35 | 19.86 | 290 | 290 | 873 | 884 |
300 | 37 | 37 | 0.11 | 0.12 | 20.67 | 21.18 | 320 | 320 | 1035 | 1047 |
350 | 37 | 37 | 0.11 | 0.12 | 21.87 | 22.38 | 350 | 350 | 1198 | 1210 |
400 | 37 | 37 | 0.11 | 0.12 | 22.99 | 23.5 | 380 | 380 | 1358 | 1371 |
500 | 37 | 37 | 0.11 | 0.12 | 25.04 | 25.55 | 430 | 430 | 1680 | 1694 |
600 | 61 | 61 | 0.125 | 0.135 | 29.03 | 29.54 | 475 | 475 | 2057 | 2073 |
750 | 61 | 61 | 0.125 | 0.135 | 31.7 | 32.21 | 535 | 535 | 2508 | 2525 |
1000 | 61 | 61 | 0.125 | 0.135 | 35.61 | 36.12 | 615 |
615 |